A comparison of ROC inferred from FROC and conventional ROC

Research output: Chapter in Book/Report/Conference proceedingsConference proceedingpeer-review

Abstract

This study aims to determine whether receiver operating characteristic (ROC) scores inferred from free-response receiver operating characteristic (FROC) were equivalent to conventional ROC scores for the same readers and cases. Forty-five examining radiologists of the American Board of Radiology independently reviewed 47 PA chest radiographs under at least two conditions. Thirty-seven cases had abnormal findings and 10 cases had normal findings. Half the readers were asked to first locate any visualized lung nodules, mark them and assign a level of confidence [the FROC mark-rating pair] and second give an overall to the entire image on the same scale [the ROC score]. The second half of readers gave the ROC rating first followed by the FROC mark-rating pairs. A normal image was represented with number 1 and malignant lesions with numbers 2-5. A jackknife free-response receiver operating characteristic (JAFROC), and inferred ROC (infROC) was calculated from the mark-rating pairs using JAFROC V4.1 software. ROC based on the overall rating of the image calculated using DBM MRMC software, which was also used to compare infROC and ROC AUCs treating the methods as modalities. Pearson's correlations coefficient and linear regression were used to examine their relationship using SPSS, version 21.0; (SPSS, Chicago, IL). The results of this study showed no significant difference between the ROC and Inferred ROC AUCs (p0.25). While Pearson's correlation coefficient was 0.7 (p0.01). Inter-reader correlation calculated from Obuchowski- Rockette covariance's ranged from 0.43-0.86 while intra-reader agreement was greater than previously reported ranging from 0.68-0.82.

Original languageEnglish
Title of host publicationMedical Imaging 2014
Subtitle of host publicationImage Perception, Observer Performance, and Technology Assessment
PublisherSPIE
ISBN (Print)9780819498304
DOIs
Publication statusPublished - 2014
Externally publishedYes
EventMedical Imaging 2014: Image Perception, Observer Performance, and Technology Assessment - San Diego, CA, United States
Duration: 16 Feb 201417 Feb 2014

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume9037
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2014: Image Perception, Observer Performance, and Technology Assessment
Country/TerritoryUnited States
CitySan Diego, CA
Period16/02/1417/02/14

Fingerprint

Dive into the research topics of 'A comparison of ROC inferred from FROC and conventional ROC'. Together they form a unique fingerprint.

Cite this