A recommendation for the use of electrical biosensing technology in neonatology

  • ESPR Special Interest Group on Non-Invasive Cardiac Output Monitoring
  • Stellenbosch University
  • Cambridge University Hospitals NHS Foundation Trust
  • Assaf Harofeh Medical Center
  • Hospital Universitario La Paz
  • University of Copenhagen
  • Charité – Universitätsmedizin Berlin
  • Radboud University Nijmegen
  • Utrecht University
  • Central Norway Regional Health Authority
  • Norwegian University of Science and Technology
  • University of Zurich
  • University of Groningen
  • Boston Children's Hospital
  • Harvard University
  • University of Iowa
  • University College London
  • University of Oslo
  • University of Sussex
  • University of Calgary
  • Royal Women's Hospital
  • University of Melbourne
  • S. Maria della Misericordia Hospital
  • IRCCS Fondazione Ca'Granda – Ospedale Maggiore Policlinico - Milano
  • Monash Children’s Hospital
  • Monash University
  • Heidelberg University 
  • Leipzig University
  • University of Antwerp
  • Iuliu Hatieganu University of Medicine and Pharmacy
  • Durham University
  • Sidra Medical and Research Center

Research output: Contribution to journalArticlepeer-review

Abstract

Abstract: Non-invasive cardiac output monitoring, via electrical biosensing technology (EBT), provides continuous, multi-parameter hemodynamic variable monitoring which may allow for timely identification of hemodynamic instability in some neonates, providing an opportunity for early intervention that may improve neonatal outcomes. EBT encompasses thoracic (TEBT) and whole body (WBEBT) methods. Despite the lack of relative accuracy of these technologies, as compared to transthoracic echocardiography, the use of these technologies in neonatology, both in the research and clinical arena, have increased dramatically over the last 30 years. The European Society of Pediatric Research Special Interest Group in Non-Invasive Cardiac Output Monitoring, a group of experienced neonatologists in the field of EBT, deemed it appropriate to provide recommendations for the use of TEBT and WBEBT in the field of neonatology. Although TEBT is not an accurate determinant of cardiac output or stroke volume, it may be useful for monitoring longitudinal changes of hemodynamic parameters. Few recommendations can be made for the use of TEBT in common neonatal clinical conditions. It is recommended not to use WBEBT to monitor cardiac output. The differences in technologies, study methodologies and data reporting should be addressed in ongoing research prior to introducing EBT into routine practice. Impact statement: TEBT is not recommended as an accurate determinant of cardiac output (CO) (or stroke volume (SV)). TEBT may be useful for monitoring longitudinal changes from baseline of hemodynamic parameters on an individual patient basis. TEBT-derived thoracic fluid content (TFC) longitudinal changes from baseline may be useful in monitoring progress in respiratory disorders and circulatory conditions affecting intrathoracic fluid volume. Currently there is insufficient evidence to make any recommendations regarding the use of WBEBT for CO monitoring in neonates. Further research is required in all areas prior to the implementation of these monitors into routine clinical practice.

Original languageEnglish
Article number41598
Pages (from-to)510-523
Number of pages14
JournalPediatric Research
Volume97
Issue number2
DOIs
Publication statusPublished - Feb 2025

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'A recommendation for the use of electrical biosensing technology in neonatology'. Together they form a unique fingerprint.

Cite this