TY - JOUR
T1 - An adaptive digital-control scheme for improved active power filtering under distorted grid conditions
AU - Hogan, Diarmaid John
AU - Gonzalez-Espin, Francisco J.
AU - Hayes, John G.
AU - Lightbody, Gordon
AU - Foley, Raymond
N1 - Publisher Copyright:
© 2017 IEEE.
PY - 2017/7/24
Y1 - 2017/7/24
N2 - The operation of active power filters (APFs) under nonideal grid conditions, such as grid-frequency fluctuation and voltage harmonics, can lead to significant degradation in harmonic compensation performance. This paper proposes an adaptive digital-control scheme for a three-phase APF for use in harmonically distorted and variable-frequency grid conditions. This scheme is comprised of a grid-frequency adaptive resonant current controller and an enhanced synchronous-reference-frame phase-locked loop (SRF-PLL). The PLL uses an inherently stable adaptive-filtering stage to improve grid phase and frequency estimates in the presence of voltage harmonics. The improved PLL frequency estimate is used to update the resonant gains of a PI + vector-proportional-integral current-control scheme, implemented in the SRF. This enables the APF to maintain optimal performance in distorted grid conditions. The performance of the proposed APF control scheme is evaluated in a test microgrid, with a 15-kVA three-phase voltage-source converter configured as the APF, a 90-kVA grid emulator utilized to replicate distorted grid conditions, and a load emulator implemented to draw harmonic currents. The control scheme presented here is shown to demonstrate significant performance improvements under nonideal grid conditions compared with equivalent adaptive and nonadaptive methods.
AB - The operation of active power filters (APFs) under nonideal grid conditions, such as grid-frequency fluctuation and voltage harmonics, can lead to significant degradation in harmonic compensation performance. This paper proposes an adaptive digital-control scheme for a three-phase APF for use in harmonically distorted and variable-frequency grid conditions. This scheme is comprised of a grid-frequency adaptive resonant current controller and an enhanced synchronous-reference-frame phase-locked loop (SRF-PLL). The PLL uses an inherently stable adaptive-filtering stage to improve grid phase and frequency estimates in the presence of voltage harmonics. The improved PLL frequency estimate is used to update the resonant gains of a PI + vector-proportional-integral current-control scheme, implemented in the SRF. This enables the APF to maintain optimal performance in distorted grid conditions. The performance of the proposed APF control scheme is evaluated in a test microgrid, with a 15-kVA three-phase voltage-source converter configured as the APF, a 90-kVA grid emulator utilized to replicate distorted grid conditions, and a load emulator implemented to draw harmonic currents. The control scheme presented here is shown to demonstrate significant performance improvements under nonideal grid conditions compared with equivalent adaptive and nonadaptive methods.
KW - Active power filter (APF)
KW - Digital control
KW - Phase-locked loop (PLL)
KW - Power quality
KW - Resonant control
UR - https://www.scopus.com/pages/publications/85029144382
U2 - 10.1109/TIE.2017.2726992
DO - 10.1109/TIE.2017.2726992
M3 - Article
AN - SCOPUS:85029144382
SN - 0278-0046
VL - 65
SP - 988
EP - 999
JO - IEEE Transactions on Industrial Electronics
JF - IEEE Transactions on Industrial Electronics
IS - 2
ER -