TY - JOUR
T1 - Continuous high-frequency monitoring of estuarine water quality as a decision support tool
T2 - A Dublin Port case study
AU - Briciu-Burghina, Ciprian
AU - Sullivan, Timothy
AU - Chapman, James
AU - Regan, Fiona
PY - 2014/9
Y1 - 2014/9
N2 - High-frequency, continuous monitoring using in situ sensors offers a comprehensive and improved insight into the temporal and spatial variability of any water body. In this paper, we describe a 7-month exploratory monitoring programme in Dublin Port, demonstrating the value of high-frequency data in enhancing knowledge of processes, informing discrete sampling, and ultimately increasing the efficiency of port and environmental management. Kruskal-Wallis and Mann-Whitney tests were used to show that shipping operating in Dublin Port has a small-medium effect on turbidity readings collected by in situ sensors. Turbidity events are largely related to vessel activity in Dublin Port, caused by re-suspension of sediments by vessel propulsion systems. The magnitudes of such events are strongly related to water level and tidal state at vessel arrival times. Crucially, measurements of Escherichia coli and enterococci contamination from discrete samples taken at key periods related to detected turbidity events were up to nine times higher after vessel arrival than prior to disturbance. Daily in situ turbidity patterns revealed time-dependent water quality "hot spots" during a 24-h period. We demonstrate conclusively that if representative environmental assessment of water quality is to be performed at such sites, sampling times, informed by continous monitoring data, should take into account these daily variations. This work outlines the potential of sensor technologies and continuous monitoring, to act as a decision support tool in both environmental and port management.
AB - High-frequency, continuous monitoring using in situ sensors offers a comprehensive and improved insight into the temporal and spatial variability of any water body. In this paper, we describe a 7-month exploratory monitoring programme in Dublin Port, demonstrating the value of high-frequency data in enhancing knowledge of processes, informing discrete sampling, and ultimately increasing the efficiency of port and environmental management. Kruskal-Wallis and Mann-Whitney tests were used to show that shipping operating in Dublin Port has a small-medium effect on turbidity readings collected by in situ sensors. Turbidity events are largely related to vessel activity in Dublin Port, caused by re-suspension of sediments by vessel propulsion systems. The magnitudes of such events are strongly related to water level and tidal state at vessel arrival times. Crucially, measurements of Escherichia coli and enterococci contamination from discrete samples taken at key periods related to detected turbidity events were up to nine times higher after vessel arrival than prior to disturbance. Daily in situ turbidity patterns revealed time-dependent water quality "hot spots" during a 24-h period. We demonstrate conclusively that if representative environmental assessment of water quality is to be performed at such sites, sampling times, informed by continous monitoring data, should take into account these daily variations. This work outlines the potential of sensor technologies and continuous monitoring, to act as a decision support tool in both environmental and port management.
KW - Faecal coliforms
KW - Sensors
KW - Ship traffic
KW - Turbidity
KW - Water monitoring
UR - https://www.scopus.com/pages/publications/84905993464
U2 - 10.1007/s10661-014-3803-9
DO - 10.1007/s10661-014-3803-9
M3 - Article
C2 - 24823471
AN - SCOPUS:84905993464
SN - 0167-6369
VL - 186
SP - 5561
EP - 5580
JO - Environmental Monitoring and Assessment
JF - Environmental Monitoring and Assessment
IS - 9
ER -