TY - GEN
T1 - Design Optimization of Micro-Thermoelectric Cooler for Thermal Management using Finite Element Simulations
AU - Kaur, Rajvinder
AU - Tanwar, Amit
AU - Gupta, Parnika
AU - Padmanathan, N.
AU - O'Brien, Peter
AU - Razeeb, Kafil M.
N1 - Publisher Copyright:
© 2022 IEEE.
PY - 2022
Y1 - 2022
N2 - Thermal Management is a key factor for optimizing the reliable performance of miniaturized optoelectronic devices. Excessive heat flux compromises the wavelength stability of the laser and directly affects the device performance, explicitly at the micro-nano scale. Therefore, advanced photonic devices require a precise thermal management system for instant heat dissipation. Micro-Thermoelectric coolers (µ-TECs) offer effective practical options for thermal management in compact photonic devices because of their active cooling and precise controllability. The cooling performance of these µ-TECs is related to the efficiency of the thermoelectric materials used to build, as well as their device architecture. As for minimizing the size of the photonic system, design optimization of the ?-TEC is required for its easy integration. In this work, we studied and analyzed the geometrical structure to optimize the design of the ?-TEC with realistic boundary conditions including electrical contact resistance. Finite element model simulations are performed using COMSOL multi-physics software. The effect of various geometrical parameters (i.e. leg height, cross-sectional area, top contact metal and fill factor) on the cooling performance of the ?-TEC are examined. The results indicate that the device's electrical and thermal resistance is affected by geometrical parameters, which leads to variation in a temperature gradient in the device. The shorter leg height of 10-20 ?m with a larger cross-sectional area, with optimum top contact and fill factor improves the device performance known as coefficient of performance (COP). The COP has increased from 0.059 to 0.067 (13%) upon enlarging the cross-section area of the p-Type leg by 4 times as compared to n-Type leg. All these results should be taken into consideration to fabricate a full ?-TEC for the thermal management of photonic integrated devices and circuits.
AB - Thermal Management is a key factor for optimizing the reliable performance of miniaturized optoelectronic devices. Excessive heat flux compromises the wavelength stability of the laser and directly affects the device performance, explicitly at the micro-nano scale. Therefore, advanced photonic devices require a precise thermal management system for instant heat dissipation. Micro-Thermoelectric coolers (µ-TECs) offer effective practical options for thermal management in compact photonic devices because of their active cooling and precise controllability. The cooling performance of these µ-TECs is related to the efficiency of the thermoelectric materials used to build, as well as their device architecture. As for minimizing the size of the photonic system, design optimization of the ?-TEC is required for its easy integration. In this work, we studied and analyzed the geometrical structure to optimize the design of the ?-TEC with realistic boundary conditions including electrical contact resistance. Finite element model simulations are performed using COMSOL multi-physics software. The effect of various geometrical parameters (i.e. leg height, cross-sectional area, top contact metal and fill factor) on the cooling performance of the ?-TEC are examined. The results indicate that the device's electrical and thermal resistance is affected by geometrical parameters, which leads to variation in a temperature gradient in the device. The shorter leg height of 10-20 ?m with a larger cross-sectional area, with optimum top contact and fill factor improves the device performance known as coefficient of performance (COP). The COP has increased from 0.059 to 0.067 (13%) upon enlarging the cross-section area of the p-Type leg by 4 times as compared to n-Type leg. All these results should be taken into consideration to fabricate a full ?-TEC for the thermal management of photonic integrated devices and circuits.
KW - Coefficient of performance (COP)
KW - Finite element simulation
KW - Micro-Thermoelectric cooler
KW - Photonic integrated circuit
KW - Thermal management
UR - https://www.scopus.com/pages/publications/85143371689
U2 - 10.1109/THERMINIC57263.2022.9950684
DO - 10.1109/THERMINIC57263.2022.9950684
M3 - Conference proceeding
AN - SCOPUS:85143371689
T3 - THERMINIC 2022 - 28th International Workshop on Thermal Investigations of ICs and Systems, Proceedings
BT - THERMINIC 2022 - 28th International Workshop on Thermal Investigations of ICs and Systems, Proceedings
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 28th International Workshop on Thermal Investigations of ICs and Systems, THERMINIC 2022
Y2 - 28 September 2022 through 30 September 2022
ER -