Abstract
To apply ergonomic task analysis to the performance of ultrasound-guided (US-guided) femoral nerve block (FNB) in an acute hospital setting.
Pilot prospective observational study.
Orthopedic operating room of a regional trauma hospital.
15 anesthesiologists of various levels of experience in US-guided FNB (estimated minimum experience < 10 procedures; maximum about 50 procedures, and from basic trainees to consultants); and 15 patients (5 men and 10 women), aged 77 ± 15 (mean ± SD yrs) years. MEASUREMENTS/OBSERVATIONS: A data capture "tool", which was modified from one previously developed for ergonomic study of spinal anesthesia, was studied. Patient, operator, and heterogeneous environmental factors related to ergonomic performance of US-guided FNB were identified. The observation period started immediately before commencement of positioning the patient and ended on completion of perineural injection. Data were acquired using direct observations, photography, and application of a questionnaire.
The quality of ergonomic performance was generally suboptimal and varied greatly among operators. Eight (experience < 10 procedures) of 15 operators excessively rotated their head, neck, and/or back to visualize the image on the ultrasound machine. Eight operators (experience < 10 procedures) performed the procedure with excessive thoracolumbar flexion.
Performance of US-guided FNB presents ergonomic challenges and was suboptimal during most of the procedures observed. Formal training in US-guided peripheral nerve blockade should include reference to ergonomic factors.
Pilot prospective observational study.
Orthopedic operating room of a regional trauma hospital.
15 anesthesiologists of various levels of experience in US-guided FNB (estimated minimum experience < 10 procedures; maximum about 50 procedures, and from basic trainees to consultants); and 15 patients (5 men and 10 women), aged 77 ± 15 (mean ± SD yrs) years. MEASUREMENTS/OBSERVATIONS: A data capture "tool", which was modified from one previously developed for ergonomic study of spinal anesthesia, was studied. Patient, operator, and heterogeneous environmental factors related to ergonomic performance of US-guided FNB were identified. The observation period started immediately before commencement of positioning the patient and ended on completion of perineural injection. Data were acquired using direct observations, photography, and application of a questionnaire.
The quality of ergonomic performance was generally suboptimal and varied greatly among operators. Eight (experience < 10 procedures) of 15 operators excessively rotated their head, neck, and/or back to visualize the image on the ultrasound machine. Eight operators (experience < 10 procedures) performed the procedure with excessive thoracolumbar flexion.
Performance of US-guided FNB presents ergonomic challenges and was suboptimal during most of the procedures observed. Formal training in US-guided peripheral nerve blockade should include reference to ergonomic factors.
| Original language | English |
|---|---|
| Pages (from-to) | 35-41 |
| Number of pages | 7 |
| Journal | Journal of Clinical Anesthesia |
| Volume | 23 |
| Issue number | 1 |
| DOIs | |
| Publication status | Published - 1 Feb 2011 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 4 Quality Education
Keywords
- Aged
- Body Height
- Data Interpretation, Statistical
- Environment
- Female
- Femur surgery
- Hip surgery
- Humans
- Knee surgery
- Male
- Middle Aged
- Pilot Projects
- Posture
- Surveys and Questionnaires
- Task Performance and Analysis
- Ultrasonography
- Ergonomics
- Femoral Nerve diagnostic imaging
- Nerve Block methods
Fingerprint
Dive into the research topics of 'Ergonomic task analysis of ultrasound-guided femoral nerve block: a pilot study.'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver