TY - CHAP
T1 - Estimation of heart rate from photoplethysmography during physical exercise using Wiener filtering and the phase vocoder
AU - Temko, Andriy
N1 - Publisher Copyright:
© 2015 IEEE.
PY - 2015/11/4
Y1 - 2015/11/4
N2 - A system for estimation of the heart rate (HR) from the photoplethysmographic (PPG) signal during intensive physical exercises is presented. The Wiener filter is used to attenuate the noise introduced by the motion artifacts in the PPG signals. The frequency with the highest magnitude estimated using Fourier transformation is selected from the resultant de-noised signal. The phase vocoder technique is exploited to refine the frequency estimate, from which the HR in beats per minute (BPM) is finally calculated. On a publically available database of twenty three PPG recordings, the proposed technique obtains an error of 2.28 BPM. A relative error rate reduction of 18% is obtained when comparing with the state-of-the art PPG-based HR estimation methods. The proposed system is shown to be robust to strong motion artifact, produces high accuracy results and has very few free parameters, in contrast to other available approaches. The algorithm has low computational cost and can be used for fitness tracking and health monitoring in wearable devices.
AB - A system for estimation of the heart rate (HR) from the photoplethysmographic (PPG) signal during intensive physical exercises is presented. The Wiener filter is used to attenuate the noise introduced by the motion artifacts in the PPG signals. The frequency with the highest magnitude estimated using Fourier transformation is selected from the resultant de-noised signal. The phase vocoder technique is exploited to refine the frequency estimate, from which the HR in beats per minute (BPM) is finally calculated. On a publically available database of twenty three PPG recordings, the proposed technique obtains an error of 2.28 BPM. A relative error rate reduction of 18% is obtained when comparing with the state-of-the art PPG-based HR estimation methods. The proposed system is shown to be robust to strong motion artifact, produces high accuracy results and has very few free parameters, in contrast to other available approaches. The algorithm has low computational cost and can be used for fitness tracking and health monitoring in wearable devices.
UR - https://www.scopus.com/pages/publications/84953313299
U2 - 10.1109/EMBC.2015.7318655
DO - 10.1109/EMBC.2015.7318655
M3 - Chapter
C2 - 26736555
AN - SCOPUS:84953313299
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 1500
EP - 1503
BT - 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2015
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2015
Y2 - 25 August 2015 through 29 August 2015
ER -