TY - JOUR
T1 - Investigating the effect of employing a 24-hour radiative cooling system on the photovoltaic/thermal systems performance
T2 - A case-based research
AU - Fakouriyan, Samaneh
AU - Mokhtari, Reza
AU - Ghasempour, Roghayeh
N1 - Publisher Copyright:
© 2024 The Authors
PY - 2024/6
Y1 - 2024/6
N2 - This study aims to investigate the potential of a renewable hybrid system that integrates a nocturnal and diurnal radiative cooling system (RC) and photovoltaic/thermal system (PV/T) as a novel system to supply highly efficient electricity, while also providing a 24-hour radiative cooling system and diurnal preheated water supply. The proposed system comprises a photovoltaic system (PV) fitted with a transparent layer instead of glass, along with two cooling systems. The first cooling system involves water flow within aluminum pipes beneath the photovoltaic panel, while the second cooling system utilizes a silicon dioxide layer as RC. The study employs a novel approach by analyzing the impact of utilizing both nocturnal and diurnal RC on PV/T performance. The results are based on simulations conducted over four days during various months of the year, including January, March, July, and October. The findings of the simulations demonstrate that the utilization of the first cooling method increases the electrical efficiency of PV by 9.1%. Furthermore, the incorporation of RC along with the first method again leads to a 3.7% increase in electrical efficiency. Additionally, the thermal efficiency is estimated to be 37.1% and 20.62% for PV/T and RC-PV/T, respectively. The cooling power of RC during the night reached 287.13 W/m2 in July. A sensitivity analysis of the input parameters reveals that variations in solar radiation and inlet water temperature have the greatest impact on the system's electrical efficiency.
AB - This study aims to investigate the potential of a renewable hybrid system that integrates a nocturnal and diurnal radiative cooling system (RC) and photovoltaic/thermal system (PV/T) as a novel system to supply highly efficient electricity, while also providing a 24-hour radiative cooling system and diurnal preheated water supply. The proposed system comprises a photovoltaic system (PV) fitted with a transparent layer instead of glass, along with two cooling systems. The first cooling system involves water flow within aluminum pipes beneath the photovoltaic panel, while the second cooling system utilizes a silicon dioxide layer as RC. The study employs a novel approach by analyzing the impact of utilizing both nocturnal and diurnal RC on PV/T performance. The results are based on simulations conducted over four days during various months of the year, including January, March, July, and October. The findings of the simulations demonstrate that the utilization of the first cooling method increases the electrical efficiency of PV by 9.1%. Furthermore, the incorporation of RC along with the first method again leads to a 3.7% increase in electrical efficiency. Additionally, the thermal efficiency is estimated to be 37.1% and 20.62% for PV/T and RC-PV/T, respectively. The cooling power of RC during the night reached 287.13 W/m2 in July. A sensitivity analysis of the input parameters reveals that variations in solar radiation and inlet water temperature have the greatest impact on the system's electrical efficiency.
KW - Photovoltaic/thermal system
KW - Radiative cooling
KW - Renewable energy
KW - Solar energy
UR - https://www.scopus.com/pages/publications/85188582316
U2 - 10.1016/j.egyr.2024.02.030
DO - 10.1016/j.egyr.2024.02.030
M3 - Article
AN - SCOPUS:85188582316
SN - 2352-4847
VL - 11
SP - 3624
EP - 3640
JO - Energy Reports
JF - Energy Reports
ER -