Abstract
A sensor capable of small volume refractive index measurements in liquids has been fabricated and tested. The measurement is based on a leaky waveguide device fabricated with Su8 on a pyrex substrate. A microfluidic channel has been integrated directly onto the fluidic sensor wafer. The device monitors the mode coupling angle to the device. The measurement of glycerol content is demonstrated.
| Original language | English |
|---|---|
| Pages | 1330-1332 |
| Number of pages | 3 |
| Publication status | Published - 2004 |
| Event | IEEE Sensors 2004 - Vienna, Austria Duration: 24 Oct 2004 → 27 Oct 2004 |
Conference
| Conference | IEEE Sensors 2004 |
|---|---|
| Country/Territory | Austria |
| City | Vienna |
| Period | 24/10/04 → 27/10/04 |
Keywords
- Leaky waveguide
- Microfluidics
- Refractive index