Low-dose CT imaging of the acute abdomen using model-based iterative reconstruction: a prospective study

Research output: Contribution to journalArticlepeer-review

Abstract

Objectives: Performance of a modified abdominopelvic CT protocol reconstructed using full iterative reconstruction (IR) was assessed for imaging patients presenting with acute abdominal symptoms. Materials and methods: Fifty-seven patients (17 male, 40 female; mean age of 56.5 ± 8 years) were prospectively studied. Low-dose (LD) and conventional-dose (CD) CTs were contemporaneously acquired between November 2015 and March 2016. The LD and CD protocols imparted radiation exposures approximating 10–20% and 80–90% those of routine abdominopelvic CT, respectively. The LD images were reconstructed with model-based iterative reconstruction (MBIR), and CD images with hybrid IR (40% adaptive statistical iterative reconstruction (ASIR)). Image quality was assessed quantitatively and qualitatively. Independent clinical interpretations were performed with a 6-week delay between reviews. Results: A 74.7% mean radiation dose reduction was achieved: LD effective dose (ED) 2.38 ± 1.78 mSv (size-specific dose estimate (SSDE) 3.77 ± 1.97 mGy); CD ED 7.04 ± 4.89 mSv (SSDE 10.74 ± 5.5 mGy). LD-MBIR images had significantly lower objective and subjective image noise compared with CD-ASIR (p < 0.0001). Noise reduction for LD-MBIR studies was greater for patients with BMI < 25 kg/m 2 than those with BMI ≥ 25 kg/m 2 (5.36 ± 3.2 Hounsfield units (HU) vs. 4.05 ± 3.1 HU, p < 0.0001). CD-ASIR studies had significantly better contrast resolution, and diagnostic acceptability (p < 0.0001 for all). LD-MBIR studies had significantly lower streak artifact (p < 0.0001). There was no difference in sensitivity for primary findings between the low-dose and conventional protocols with the exception of one case of enteritis. Conclusions: Low-dose abdominopelvic CT performed with MBIR is a feasible radiation dose reduction strategy for imaging patients presenting with acute abdominal pain.

Original languageEnglish
Pages (from-to)169-177
Number of pages9
JournalEmergency Radiology
Volume26
Issue number2
DOIs
Publication statusPublished - 10 Apr 2019

Keywords

  • Acute abdominal imaging
  • Computed tomography
  • Dose optimization
  • Iterative reconstruction
  • Radiation dose reduction

Fingerprint

Dive into the research topics of 'Low-dose CT imaging of the acute abdomen using model-based iterative reconstruction: a prospective study'. Together they form a unique fingerprint.

Cite this