Abstract
Aim To examine how the location where reading takes place and the availability of prior images can affect performance in breast test-set reading. Materials and methods Under optimized viewing conditions, 10 expert screen readers each interpreted a reader-specific set of images containing 200 mammographic cases. Readers, randomly divided into two groups read images under one of two pairs of conditions: clinical read with prior images and laboratory read with prior images; laboratory read with prior images and laboratory read without prior images. Region-of-interest (ROI) figure-of-merit (FOM) was analysed using JAFROC software. Breast side-specific sensitivity and specificity were tested using Wilcoxon matched-pairs signed rank tests. Agreement between pairs of readings was measured using Kendall's coefficient of concordance. Results Group performances between test-set readings demonstrated similar ROI FOMs, sensitivity and specificity median values, and acceptable levels of agreement between pairs of readings were shown (W = 0.75-0.79, p < 0.001) for both pairs of reading conditions. On an individual reader level, two readers demonstrated significant decreases (p < 0.05) in ROI FOMs when prior images were unavailable. Reading location had an inconsistent impact on individual performance. Conclusion Reading location and availability of prior images did not significantly alter group performance.
| Original language | English |
|---|---|
| Pages (from-to) | 397-402 |
| Number of pages | 6 |
| Journal | Clinical Radiology |
| Volume | 69 |
| Issue number | 4 |
| DOIs | |
| Publication status | Published - Apr 2014 |
| Externally published | Yes |