Monitoring of binder removal from injection molded ceramics using air-coupled ultrasound at high temperature

Research output: Contribution to journalArticlepeer-review

Abstract

A pair of capacitance-type air-coupled ultrasonic transducers have been constructed that were capable of operating in air at temperatures of 500 to 600°C. These devices were then used to monitor the pyrolytic removal of organic binder from injection molded silicon nitride ceramic components using air-coupled ultrasound inside a furnace at elevated temperatures. Through-thickness waveforms were obtained in the ceramic and compared with simultaneous measurements of the mass of the sample. Both the ultrasonic velocity and signal amplitudes could be used to monitor the change in mass of the injection molded ceramic, and other phenomena (such as softening and redistribution of the binder) were observed.

Original languageEnglish
Pages (from-to)647-653
Number of pages7
JournalIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Volume46
Issue number3
DOIs
Publication statusPublished - 1999

Fingerprint

Dive into the research topics of 'Monitoring of binder removal from injection molded ceramics using air-coupled ultrasound at high temperature'. Together they form a unique fingerprint.

Cite this