TY - JOUR
T1 - Profiling of phenolic flavorings using core-shell reversed-phase liquid chromatography with electrochemical detection at a boron-doped diamond electrode
AU - Hayes, Phyllis E.
AU - Luong, John H.T.
AU - Gilchrist, Elizabeth S.
AU - Buzid, Alyah
AU - Glennon, Jeremy D.
N1 - Publisher Copyright:
© 2019 Elsevier B.V.
PY - 2020/2/8
Y1 - 2020/2/8
N2 - A high-performance liquid chromatography (HPLC) method equipped with a boron-doped diamond (BDD) electrode was established for the simultaneous determination of phenol, 4-ethylphenol (4-EP), guaiacol, 4-ethylguaiacol (4-EG), 4-vinylguaiacol (4-VG), eugenol, and o-, m- and p-cresol. The separation was performed on a reversed-phase HALO C18 core-shell column (3.0 × 50 mm, 2.7 µm) with a mobile phase comprising 10 mM formate, pH 3, and 15% acetonitrile (ACN) (v/v), a flow rate of 1.5 mL/min, corresponding to a total run time of 9 min. The electrochemical detection (ECD) was set at +1.5 V vs. Pd/H2 in oxidative mode. Under optimized operating conditions, good linearity was obtained for the nine phenolics with corresponding coefficients of determination (R2) above 0.998. The limits of detection (LODs, S/N = 3) were 10 nM–1 µM, with an 80-fold increase in sensitivity for guaiacol achieved with ECD over ultraviolet (UV) detection. The sensitive and selective HPLC-ECD method was successfully applied for the identification and quantification of the nine phenolics in Islay, Irish, Scotch, and Highland whiskey samples, with significantly higher concentrations of the flavorings determined in Islay whiskey.
AB - A high-performance liquid chromatography (HPLC) method equipped with a boron-doped diamond (BDD) electrode was established for the simultaneous determination of phenol, 4-ethylphenol (4-EP), guaiacol, 4-ethylguaiacol (4-EG), 4-vinylguaiacol (4-VG), eugenol, and o-, m- and p-cresol. The separation was performed on a reversed-phase HALO C18 core-shell column (3.0 × 50 mm, 2.7 µm) with a mobile phase comprising 10 mM formate, pH 3, and 15% acetonitrile (ACN) (v/v), a flow rate of 1.5 mL/min, corresponding to a total run time of 9 min. The electrochemical detection (ECD) was set at +1.5 V vs. Pd/H2 in oxidative mode. Under optimized operating conditions, good linearity was obtained for the nine phenolics with corresponding coefficients of determination (R2) above 0.998. The limits of detection (LODs, S/N = 3) were 10 nM–1 µM, with an 80-fold increase in sensitivity for guaiacol achieved with ECD over ultraviolet (UV) detection. The sensitive and selective HPLC-ECD method was successfully applied for the identification and quantification of the nine phenolics in Islay, Irish, Scotch, and Highland whiskey samples, with significantly higher concentrations of the flavorings determined in Islay whiskey.
KW - Boron-doped diamond electrode
KW - Core-shell
KW - High-performance liquid chromatography
KW - Phenolic flavorings
KW - Whiskey
UR - https://www.scopus.com/pages/publications/85075339144
U2 - 10.1016/j.chroma.2019.460649
DO - 10.1016/j.chroma.2019.460649
M3 - Article
C2 - 31708221
AN - SCOPUS:85075339144
SN - 0021-9673
VL - 1612
JO - Journal of Chromatography A
JF - Journal of Chromatography A
M1 - 460649
ER -