Radiomic study of antenatal prediction of severe placenta accreta spectrum from MRI

  • Helena C. Bartels
  • , Eric Wolsztynski
  • , Jim O. Doherty
  • , David P. Brophy
  • , Roisin MacDermott
  • , David Atallah
  • , Souha Saliba
  • , Nadine El Kassis
  • , Malak Moubarak
  • , Constance Young
  • , Paul Downey
  • , Jennifer Donnelly
  • , Tony Geoghegan
  • , Donal J. Brennan
  • , Kathleen M. Curran

Research output: Contribution to journalArticlepeer-review

Abstract

Objectives: We previously demonstrated the potential of radiomics for the prediction of severe histological placenta accreta spectrum (PAS) subtypes using T2-weighted MRI. We aim to validate our model using an additional dataset. Secondly, we explore whether the performance is improved using a new approach to develop a new multivariate radiomics model. Methods: Multi-centre retrospective analysis was conducted between 2018 and 2023. Inclusion criteria: MRI performed for suspicion of PAS from ultrasound, clinical findings of PAS at laparotomy and/or histopathological confirmation. Radiomic features were extracted from T2-weighted MRI. The previous multivariate model was validated. Secondly, a 5-radiomic feature random forest classifier was selected from a randomized feature selection scheme to predict invasive placenta increta PAS cases. Prediction performance was assessed based on several metrics including area under the curve (AUC) of the receiver operating characteristic curve (ROC), sensitivity, and specificity. Results: We present 100 women [mean age 34.6 (±3.9) with PAS], 64 of whom had placenta increta. Firstly, we validated the previous multivariate model and found that a support vector machine classifier had a sensitivity of 0.620 (95% CI: 0.068; 1.0), specificity of 0.619 (95% CI: 0.059; 1.0), an AUC of 0.671 (95% CI: 0.440; 0.922), and accuracy of 0.602 (95% CI: 0.353; 0.817) for predicting placenta increta. From the new multivariate model, the best 5-feature subset was selected via the random subset feature selection scheme comprised of 4 radiomic features and 1 clinical variable (number of previous caesareans). This clinical-radiomic model achieved an AUC of 0.713 (95% CI: 0.551; 0.854), accuracy of 0.695 (95% CI 0.563; 0.793), sensitivity of 0.843 (95% CI 0.682; 0.990), and specificity of 0.447 (95% CI 0.167; 0.667). Conclusion: We validated our previous model and present a new multivariate radiomic model for the prediction of severe placenta increta from a well-defined, cohort of PAS cases. Advances in knowledge: Radiomic features demonstrate good predictive potential for identifying placenta increta. This suggests radiomics may be a useful adjunct to clinicians caring for women with this high-risk pregnancy condition.

Original languageEnglish
Pages (from-to)1833-1842
Number of pages10
JournalBritish Journal of Radiology
Volume97
Issue number1163
DOIs
Publication statusPublished - 1 Nov 2024

Keywords

  • machine learning
  • MRI
  • placenta accreta spectrum
  • pregnancy
  • radiomics

Fingerprint

Dive into the research topics of 'Radiomic study of antenatal prediction of severe placenta accreta spectrum from MRI'. Together they form a unique fingerprint.

Cite this