TY - JOUR
T1 - Reducing dose for digital cranial radiography
T2 - The increased source to the image-receptor distance approach
AU - Joyce, Maria
AU - McEntee, Mark
AU - Brennan, Patrick C.
AU - O'Leary, Desiree
PY - 2013/12
Y1 - 2013/12
N2 - This investigation proposes that an increased source to the image-receptor distance (SID) technique can be used to optimize occipital frontal and lateral cranial radiographs acquired with direct digital radiography. Although cranial radiography is not performed on a routine basis, it should nonetheless be optimized to keep the dose to the patient as low as reasonably achievable, particularly because it can form part of the facial bone and sinus series. Dose measurements were acquired at various SIDs, and image quality was assessed using visual grading analysis. Statistically significant reductions in the effective dose between 19.2% and 23.9% were obtained when the SID was increased from the standard 100 to 150 cm (P ≤.05), and visual grading analysis scores indicate that image quality remained diagnostically acceptable for both projections. This investigation concludes that increasing the SID effectively optimizes occipital frontal and lateral skull radiographs. Radiology departments must be advised of the benefits of this technique with the goal of introducing an updated reference SID of 150 cm into clinical practice.
AB - This investigation proposes that an increased source to the image-receptor distance (SID) technique can be used to optimize occipital frontal and lateral cranial radiographs acquired with direct digital radiography. Although cranial radiography is not performed on a routine basis, it should nonetheless be optimized to keep the dose to the patient as low as reasonably achievable, particularly because it can form part of the facial bone and sinus series. Dose measurements were acquired at various SIDs, and image quality was assessed using visual grading analysis. Statistically significant reductions in the effective dose between 19.2% and 23.9% were obtained when the SID was increased from the standard 100 to 150 cm (P ≤.05), and visual grading analysis scores indicate that image quality remained diagnostically acceptable for both projections. This investigation concludes that increasing the SID effectively optimizes occipital frontal and lateral skull radiographs. Radiology departments must be advised of the benefits of this technique with the goal of introducing an updated reference SID of 150 cm into clinical practice.
UR - https://www.scopus.com/pages/publications/84888637869
U2 - 10.1016/j.jmir.2013.07.002
DO - 10.1016/j.jmir.2013.07.002
M3 - Article
AN - SCOPUS:84888637869
SN - 1939-8654
VL - 44
SP - 180
EP - 187
JO - Journal of Medical Imaging and Radiation Sciences
JF - Journal of Medical Imaging and Radiation Sciences
IS - 4
ER -