TY - JOUR
T1 - Temporal Changes in Intraluminal Thrombus Volume Within Abdominal Aortic Aneurysms
T2 - Implications for Planning Endovascular Aneurysm Sealing
AU - Paraskevas, Kosmas I.
AU - Torella, Francesco
AU - Swaelens, Charles
AU - England, Andrew
AU - Chan, Tze Y.
AU - Shaikh, Usman
AU - McWilliams, Richard G.
AU - Fisher, Robert K.
N1 - Publisher Copyright:
© 2017, © The Author(s) 2017.
PY - 2018/2/1
Y1 - 2018/2/1
N2 - Purpose: To explore whether or not there are temporal changes in the abdominal aortic aneurysm (AAA) and intraluminal thrombus (ILT) volumes between planning and implantation of the endovascular aneurysm sealing (EVAS) device and how these changes influence lumen volume. Methods: A retrospective review was conducted of 51 AAA patients (mean age 76±7.1 years; 36 men) in whom 2 serial preoperative computed tomography angiograms (CTAs) had been performed within 1 to 18 months before fenestrated endovascular repair. The 2 preoperative CTAs were analyzed to identify changes in total sac, ILT, and lumen volumes. Results: Over a median 7.0 months (interquartile range 4, 10), 46 (90%) of 51 AAAs increased in volume between the 2 CTAs. ILT volume increased in 44 aneurysms. In contrast, lumen volume increased in 31 and decreased in 20 AAAs. There was a strong correlation between changes in AAA volume and ILT volume (rs=0.859, p<0.001), which remained significant after adjustment for initial volumes (rs=0.815; p<0.001). There was no correlation between the time interval separating the 2 CTAs and changes in AAA volume (rs=0.115; p=0.421), changes in ILT volume (rs=0.084; p=0.599), or changes in lumen volume (rs=0.060; p=0.676). The AAA growth rate (defined as the change in AAA size/days between CTAs) showed a weak correlation with ILT volume (rs=0.272, p=0.054), which disappeared after adjustment for initial AAA size (rs=−0.002, p=0.991). Between the 2 CTAs, 12 aneurysms crossed the new <1.4 Nellix maximum aorta/lumen diameter ratio. Conclusion: As AAAs grow, the increase in aortic volume is largely occupied by additional ILT formation, with minimal change in lumen volume. These changes may alter the suitability of the aneurysm for the Nellix device and could have implications for EVAS planning and device deployment.
AB - Purpose: To explore whether or not there are temporal changes in the abdominal aortic aneurysm (AAA) and intraluminal thrombus (ILT) volumes between planning and implantation of the endovascular aneurysm sealing (EVAS) device and how these changes influence lumen volume. Methods: A retrospective review was conducted of 51 AAA patients (mean age 76±7.1 years; 36 men) in whom 2 serial preoperative computed tomography angiograms (CTAs) had been performed within 1 to 18 months before fenestrated endovascular repair. The 2 preoperative CTAs were analyzed to identify changes in total sac, ILT, and lumen volumes. Results: Over a median 7.0 months (interquartile range 4, 10), 46 (90%) of 51 AAAs increased in volume between the 2 CTAs. ILT volume increased in 44 aneurysms. In contrast, lumen volume increased in 31 and decreased in 20 AAAs. There was a strong correlation between changes in AAA volume and ILT volume (rs=0.859, p<0.001), which remained significant after adjustment for initial volumes (rs=0.815; p<0.001). There was no correlation between the time interval separating the 2 CTAs and changes in AAA volume (rs=0.115; p=0.421), changes in ILT volume (rs=0.084; p=0.599), or changes in lumen volume (rs=0.060; p=0.676). The AAA growth rate (defined as the change in AAA size/days between CTAs) showed a weak correlation with ILT volume (rs=0.272, p=0.054), which disappeared after adjustment for initial AAA size (rs=−0.002, p=0.991). Between the 2 CTAs, 12 aneurysms crossed the new <1.4 Nellix maximum aorta/lumen diameter ratio. Conclusion: As AAAs grow, the increase in aortic volume is largely occupied by additional ILT formation, with minimal change in lumen volume. These changes may alter the suitability of the aneurysm for the Nellix device and could have implications for EVAS planning and device deployment.
KW - abdominal aortic aneurysm
KW - deployment
KW - diameter
KW - endograft
KW - endovascular aneurysm sealing
KW - intraluminal thrombus
KW - procedure planning
KW - stent-graft
KW - volume
UR - https://www.scopus.com/pages/publications/85040715204
U2 - 10.1177/1526602817748585
DO - 10.1177/1526602817748585
M3 - Article
C2 - 29251206
AN - SCOPUS:85040715204
SN - 1526-6028
VL - 25
SP - 47
EP - 51
JO - Journal of Endovascular Therapy
JF - Journal of Endovascular Therapy
IS - 1