Abstract
Aim: To investigate the level of agreement between test sets and actual clinical reading Background: The performance of screen readers in detecting breast cancer is being assessed in some countries by using mammographic test sets. However, previous studies have provided little evidence that performance assessed by test sets strongly correlate to performance in clinical reading. Methods: Five clinicians from BreastScreen New South Wales participated in this study. Each clinician was asked to read 200 de-identified mammographic examinations gathered from their own case history within the BreastScreen NSW Digital Imaging Library. All test sets were designed with specific proportions of true positive, true negative, false positive and false negative examinations from the previous actual clinical reads of each reader. A prior mammogram examination for comparison (when available) was also provided for each case. Results: Preliminary analyses have shown that there is a moderate level of agreement (Kappa 0.42-0.56, p< 0.001) between laboratory test sets and actual clinical reading. In addition, a mean increase of 38% in sensitivity in the laboratory test sets as compared to their actual clinical readings was demonstrated. Specificity is similar between the laboratory test sets and actual clinical reading. Conclusion: This study demonstrated a moderate level of agreement between actual clinical reading and test set reading, which suggests that test sets have a role in reflecting clinical performance.
| Original language | English |
|---|---|
| Title of host publication | Medical Imaging 2013 |
| Subtitle of host publication | Image Perception, Observer Performance, and Technology Assessment |
| DOIs | |
| Publication status | Published - 2013 |
| Externally published | Yes |
| Event | SPIE Medical Imaging Symposium 2013: Image Perception, Observer Performance, and Technology Assessment - Lake Buena Vista, FL, United States Duration: 10 Feb 2013 → 11 Feb 2013 |
Publication series
| Name | Proceedings of SPIE - The International Society for Optical Engineering |
|---|---|
| Volume | 8673 |
| ISSN (Print) | 0277-786X |
| ISSN (Electronic) | 1996-756X |
Conference
| Conference | SPIE Medical Imaging Symposium 2013: Image Perception, Observer Performance, and Technology Assessment |
|---|---|
| Country/Territory | United States |
| City | Lake Buena Vista, FL |
| Period | 10/02/13 → 11/02/13 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 3 Good Health and Well-being
Keywords
- Breast screening
- Level of agreement
- Mammography
- Performance
- Test sets
Fingerprint