@inbook{a2472ce67c8c45e29f377c876b172269,
title = "Theoretical study of combined acousto-optical tomography and slow light filters",
abstract = "Monte Carlo simulations were used to determine the contrast-to-noise ratio of acoustooptical tomographic imaging with slow light filters versus possible imaging depth. Both reflection and transmission setups were considered. The theoretical model showed that imaging through 12 cm of breast tissue could be plausible.",
author = "Jacqueline Gunther and Andreas Walther and Lars Rippe and Stefan Kr{\"o}ll and Stefan Andersson-Engels",
note = "Publisher Copyright: {\textcopyright} OSA 2018.; Optical Tomography and Spectroscopy, OTS 2018 ; Conference date: 03-04-2018 Through 06-04-2018",
year = "2018",
doi = "10.1364/OTS.2018.OF1D.3",
language = "English",
isbn = "9781943580415",
series = "Optics InfoBase Conference Papers",
publisher = "Optica Publishing Group (formerly OSA)",
booktitle = "Optical Tomography and Spectroscopy, OTS 2018",
address = "United States",
}