TY - JOUR
T1 - Transfusional fetal complications after single intrauterine death in monochorionic multiple pregnancy are reduced but not prevented by vascular occlusion
AU - O'Donoghue, K.
AU - Rutherford, M. A.
AU - Engineer, N.
AU - Wimalasundera, R. C.
AU - Cowan, F. M.
AU - Fisk, N. M.
PY - 2009/5
Y1 - 2009/5
N2 - Please cite this paper as: O'Donoghue K, Rutherford M, Engineer N, Wimalasundera R, Cowan F, Fisk N. Transfusional fetal complications after single intrauterine death in monochorionic multiple pregnancy are reduced but not prevented by vascular occlusion. BJOG 2009;116:804-812.Objective To document co-twin death/pregnancy loss and brain injury after single intrauterine death (sIUD) in monochorionic pregnancies. Design A total of 135 pregnancies with sIUD were reviewed for co-twin IUD, miscarriage and abnormal antenatal and postnatal neuro-imaging. Setting A tertiary referral fetal medicine unit from 2000 to 2007. Population or Sample All cases referred with a single fetal death in monochorionic pregnancy, including those where sIUD was spontaneous or occurred after fetoscopic laser treatment, or resulted from selective termination by cord occlusion with bipolar diathermy or intrafetal vascular ablation with interstitial laser. Methods Clinical details and ultrasound findings of the study population were retrieved from ultrasound and institutional databases. Delivery and neonatal outcome data were obtained from discharge summaries supplemented by individual chart review. Main outcome measures Co-twin death or pregnancy loss and neurologic injury assessed on antenatal ultrasound and MR-imaging. Results A total of 81 sIUDs resulted from vascular occlusive feticide (diathermy or interstitial laser), 22 followed placental laser and 32 were spontaneous. In 22 pregnancies (16.8%), the co-twin died in utero and eight pregnancies miscarried (6.1%). Antenatal magnetic resonance (MR) imaging in 76/91 (83.5%) continuing pregnancies detected antenatal brain injury in five (6.6%). Three infants (two not scanned antenatally) had abnormalities detected postnatally. Brain abnormality was detected less often after procedure related (2.6%, 2/77) than spontaneous sIUD (22.2%, 6/27, P = 0.003) and after early compared with late gestation sIUD (3.6%, 4/111 versus 20.0%, 4/20; P = 0.02). Conclusions We confirm substantial co-twin loss (22.9%) after monochorionic sIUD, but a low risk of antenatally acquired MRI-identified brain injury, suggesting this risk has been overestimated. Procedures restricting inter-twin transfusion reduce, but do not negate risk of brain injury.
AB - Please cite this paper as: O'Donoghue K, Rutherford M, Engineer N, Wimalasundera R, Cowan F, Fisk N. Transfusional fetal complications after single intrauterine death in monochorionic multiple pregnancy are reduced but not prevented by vascular occlusion. BJOG 2009;116:804-812.Objective To document co-twin death/pregnancy loss and brain injury after single intrauterine death (sIUD) in monochorionic pregnancies. Design A total of 135 pregnancies with sIUD were reviewed for co-twin IUD, miscarriage and abnormal antenatal and postnatal neuro-imaging. Setting A tertiary referral fetal medicine unit from 2000 to 2007. Population or Sample All cases referred with a single fetal death in monochorionic pregnancy, including those where sIUD was spontaneous or occurred after fetoscopic laser treatment, or resulted from selective termination by cord occlusion with bipolar diathermy or intrafetal vascular ablation with interstitial laser. Methods Clinical details and ultrasound findings of the study population were retrieved from ultrasound and institutional databases. Delivery and neonatal outcome data were obtained from discharge summaries supplemented by individual chart review. Main outcome measures Co-twin death or pregnancy loss and neurologic injury assessed on antenatal ultrasound and MR-imaging. Results A total of 81 sIUDs resulted from vascular occlusive feticide (diathermy or interstitial laser), 22 followed placental laser and 32 were spontaneous. In 22 pregnancies (16.8%), the co-twin died in utero and eight pregnancies miscarried (6.1%). Antenatal magnetic resonance (MR) imaging in 76/91 (83.5%) continuing pregnancies detected antenatal brain injury in five (6.6%). Three infants (two not scanned antenatally) had abnormalities detected postnatally. Brain abnormality was detected less often after procedure related (2.6%, 2/77) than spontaneous sIUD (22.2%, 6/27, P = 0.003) and after early compared with late gestation sIUD (3.6%, 4/111 versus 20.0%, 4/20; P = 0.02). Conclusions We confirm substantial co-twin loss (22.9%) after monochorionic sIUD, but a low risk of antenatally acquired MRI-identified brain injury, suggesting this risk has been overestimated. Procedures restricting inter-twin transfusion reduce, but do not negate risk of brain injury.
KW - Acute twin-twin transfusion
KW - Fetal brain injury
KW - Intrauterine death
KW - Monochorionic multiple pregnancy
UR - https://www.scopus.com/pages/publications/65349159731
U2 - 10.1111/j.1471-0528.2009.02128.x
DO - 10.1111/j.1471-0528.2009.02128.x
M3 - Article
C2 - 19432569
AN - SCOPUS:65349159731
SN - 1470-0328
VL - 116
SP - 804
EP - 812
JO - BJOG: An International Journal of Obstetrics and Gynaecology
JF - BJOG: An International Journal of Obstetrics and Gynaecology
IS - 6
ER -