Uncertainty in Wave Basin Testing of a Fixed Oscillating Water Column Wave Energy Converter

Research output: Contribution to journalArticlepeer-review

Abstract

This research presents a methodology for carrying out uncertainty analysis on measurements made during wave basin testing of an oscillating water column wave energy converter. Values are determined for type A and type B uncertainty for each parameter of interest, and uncertainty is propagated using the Monte Carlo method to obtain an overall expanded uncertainty with a 95% confidence level associated with the capture width ratio of the device. An investigation into the impact of reflections on the experimental results reveals the importance of identifying the incident and combined wave field at each measurement location used to determine device performance, in order to avoid misleading results.

Original languageEnglish
Article number040902 EN
JournalASCE-ASME Journal of Risk and Uncertainty in Engineering Systems, Part B: Mechanical Engineering
Volume7
Issue number4
DOIs
Publication statusPublished - 1 Dec 2021

Fingerprint

Dive into the research topics of 'Uncertainty in Wave Basin Testing of a Fixed Oscillating Water Column Wave Energy Converter'. Together they form a unique fingerprint.

Cite this