TY - JOUR
T1 - Video rasterstereography of the spine and pelvis in eight erect positions
T2 - A reliability study
AU - Alzyoud, K.
AU - Hogg, P.
AU - Snaith, B.
AU - Preece, S.
AU - England, A.
N1 - Publisher Copyright:
© 2019 The College of Radiographers
PY - 2020/2
Y1 - 2020/2
N2 - Introduction: To investigate the reliability and variability of Video Rasterstereography (VR) measurements of the spine and pelvis, for eight proposed standing postures, in order to help define an optimal standing position for erect pelvis radiography. Methods: Surface topography data were collected using the formetic 4D dynamic modelling (Diers) system. 61 healthy participants were recruited; each participant performed eight different standing positions. Four positions were performed with the feet shoulder width apart and parallel, and four positions were performed with the feet shoulder width apart and internally rotated. For the upper extremity, each of the (two sets of) four positions were performed with different arm positions (arms by the sides, arms crossed over the chest, arms 30° flexed and touching the medial end of the clavicle, arms 30° flexed with the hands holding a support). Three sets of surface topography were collected in the eight positions (n = 24). The variability was assessed by calculating standard error of the measurement (SEm) and the coefficient of variation (CV). Reliability was assessed using intra-class correlation coefficients (ICC ± 95% CI). Results: No significant differences in the SEm were found between the three paired measurements for all standing positions (P > 0.05). ICC values demonstrated excellent reliability for all measurements across the eight standing positions (range 0.879–1.00 [95% CI 0.813–1.00]). Conclusion: Evaluating eight standing positions radiographically would be unethical as it would involve repeat radiation exposures. Using the formetic 4D dynamic modelling (Diers) system, provides an alternative and has shown that there was only a minimal, non-statistically significant, differences between the eight different standing positions. Implication for practice: Different standing positions were proposed for erect pelvis radiography.
AB - Introduction: To investigate the reliability and variability of Video Rasterstereography (VR) measurements of the spine and pelvis, for eight proposed standing postures, in order to help define an optimal standing position for erect pelvis radiography. Methods: Surface topography data were collected using the formetic 4D dynamic modelling (Diers) system. 61 healthy participants were recruited; each participant performed eight different standing positions. Four positions were performed with the feet shoulder width apart and parallel, and four positions were performed with the feet shoulder width apart and internally rotated. For the upper extremity, each of the (two sets of) four positions were performed with different arm positions (arms by the sides, arms crossed over the chest, arms 30° flexed and touching the medial end of the clavicle, arms 30° flexed with the hands holding a support). Three sets of surface topography were collected in the eight positions (n = 24). The variability was assessed by calculating standard error of the measurement (SEm) and the coefficient of variation (CV). Reliability was assessed using intra-class correlation coefficients (ICC ± 95% CI). Results: No significant differences in the SEm were found between the three paired measurements for all standing positions (P > 0.05). ICC values demonstrated excellent reliability for all measurements across the eight standing positions (range 0.879–1.00 [95% CI 0.813–1.00]). Conclusion: Evaluating eight standing positions radiographically would be unethical as it would involve repeat radiation exposures. Using the formetic 4D dynamic modelling (Diers) system, provides an alternative and has shown that there was only a minimal, non-statistically significant, differences between the eight different standing positions. Implication for practice: Different standing positions were proposed for erect pelvis radiography.
KW - Erect pelvis radiograph
KW - Pelvis tilt
KW - Posture
KW - Video rasterstereography
UR - https://www.scopus.com/pages/publications/85068013982
U2 - 10.1016/j.radi.2019.06.002
DO - 10.1016/j.radi.2019.06.002
M3 - Article
C2 - 31902465
AN - SCOPUS:85068013982
SN - 1078-8174
VL - 26
SP - e7-e13
JO - Radiography
JF - Radiography
IS - 1
ER -